TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING
IEC 60598-1, Edition 8.0 (2014)
Luminaires – Part 1: General requirements and tests
点我下载完整版/Click to download the full version:http://bbs.ulccc.cn/thread-8853-1-1.html
“R” Required
“S” May be subcontracted, see OD 2012
“SF” Specialized Facility, see IECEE 02-2
“W” Witness testing in the categories “MED” and “MEAS”
“3PPS” Three Phase Power Supply required
Clause | Measurement/testing | Testing / measuring equipment / material needed | Subcontracting |
3.4 | Test of marking | Piece of cloth / Water / Petroleum spirit | R |
4.4.4 | Lampholder pressure test | Test caps / Pressure device / Torque driver | R |
4.4.5 | Voltage across lampholders | High voltage probe / Oscilloscope | R |
4.11.6 | Electro-mechanical contact system | Low voltage variable current power supply, voltmeter, high voltage transformer | R |
4.12.1/4.12.5 | Screws and connections (mechanical) and glands testing | Test screwdriver or spanner / Test rods | R |
4.13.1/4.13.44.13.6/4.21.4 |
Mechanical strength tests | Spring-operated impact test apparatus / Apparatus for ball impact tests / Conditioning cabinet (e.g. freezer) / Angle measuring device / Weighting device / Tumbling barrel test equipment |
R |
4.14.1/4.14.2 4.14.3 | Adjusting devices testing | Glass test shelves / Weighting device / Test apparatus for adjustable devices | R |
4.9.2/4.18.1 | Insulating linings and sleeves tests / Resistance to corrosion | Heating cabinet, humidity cabinet, megaohmeter, high voltage transformer | R |
4.18.2 / Annex F | Stress corrosion | Closeable glass vessel / test solution / Heating cabinet / Facilities to wash samples after test | R |
4.20 | Rough service luminaires | Vibration test equipment | S |
4.22 | Attachment to lamps | Weighing device | R |
4.24/Annex P | Photobiological hazard: UV radiation, retinal blue light hazard | UV radiation test instruments / retinal blue light hazard test instruments (Equipment List of IEC/TR 62778:2012, Edition 1.0) Goniophotometric measurement system |
S |
4.26 | Short circuit protection test | Test chain / Weighting device | R |
4.28 | Fixing of thermal sensing controls | Temperature change test instruments in accordance to IEC 60068-2-14, test Na | S |
5.2.10.1 | Pull and torque tests on cord anchorage | Cord anchorage tests apparatus (pull and torque) | R |
5.3 | Internal wiring dimensions | Micrometer / Equipment for insulation thickness | R |
7.2.3 | Earth continuity test | Earthing test equipment | R |
8.2.5 8.2.7 | Protection against electric shock tests / Capacitor discharge | Standard test finger (IEC 60529) / Unjointed test finger Voltmeter / oscilloscope | R
|
9.2.0 | Solid object proof luminaire testing | IP 3X (2,5 mm) / IP 4X (1 mm) probes | R |
9.2.1/9.2.2 | Dust proof luminaire tests | Apparatus for proving protection against dust | R |
9.2.3,4,5,6,7, 8,9 | Water proof luminaires testing | Apparatus for protection against water tests | R |
9.3.1 | Humidity tests | Humidity cabinet | R |
10.2.1 | Insulation resistance tests | Megaohmmeter | R |
10.2.2 | Electric strength tests | High voltage transformer | R |
10.3.1 | Leakage current testing | Leakage current tester | R |
11.2.1 | Creepage distances and clearances measurements | Digital calliper (or equivalent) | R |
12.3.1 | Endurance tests | Thermal cabinet (35°C) / Endurance test equipment / Multimeter / Wattmeter | R |
12.4.1 | Thermal tests | Draught-proof enclosure (25°C) / Thermometer / Thermocouples / Voltage stabilizer / Multimeter / Wattmeter | R |
12.5.1e) Annex C Fig. C3 |
Abnormal operation testing |
Test circuit for metal halide luminaires |
R |
12.7.2 | Test for luminaires with temperature sensing controls internal/external to the ballast or transformer | Relevant equipment of clauses 15.3 and 20.5, Equipment List of IEC 61558-1, Edition 2 - 2005 |
R |
13.2.1 | Resistance to heat test | Heating cabinet / Ball pressure test apparatus (see also CTL D.S. N. 391.mod) | R |
13.3.1 | Resistance to flame test | Needle flame test apparatus | R |
13.3.2 | Resistance to ignition testing | Glow-wire test apparatus | R |
13.4.1 | Resistance to tracking test | Proof tracking test device | R |
14 | Screw terminals | Torque drivers, test cables, pull device, micrometer, timer | R |
15 | Screwless terminals | Pull device, variable current source, voltmeter, heating cabinet, timer, test cables | R |