灼热丝试验校温银箔|灼热丝银箔|0.06mm标准银箔片|灼热丝试验仪用银箔片|Silver leaf for Verification temperature of Glow-wire

灼热丝试验校温银箔|灼热丝银箔|0.06mm标准银箔片|灼热丝试验仪用银箔片|Silver leaf for Verification temperature of Glow-wire美华安规仪器|安规仪器网:销售的高纯度银箔100% 满足标准(检测报告见底下)前提下,价格全国最平,请与同行比较纯度,材质和价格,也欢迎销售商/代理商和检测实验室, 大学,研究院,工厂等咨询和购买。美华安规型号: M

灼热丝试验校温银箔|灼热丝银箔|0.06mm标准银箔片|灼热丝试验仪用银箔片|Silver leaf for Verification temperature of Glow-wire

美华安规仪器|安规仪器网:销售的高纯度银箔100% 满足标准(检测报告见底下)前提下,价格全国最平,请与同行比较纯度,材质和价格,也欢迎销售商/代理商和检测实验室, 大学,研究院,工厂等咨询和购买。

美华安规型号: MH-60695210B

灼热丝标准:

GB/T5169.10-2006着火危险试验--第2-10部分:基于灼热/热线试验方法--灼热线装置及通用试验程序

IEC 60695-2-10-2013 Fire hazard testing--Part 2-10: Glowing/hot-wire based test methods -- Glow-wire apparatus and common test procedure(或最新版要求):

灼热丝银箔参数/Product parameter

材质/Material:高纯银箔

纯度/Purity:≥99.99%(ic-ag99.99)

尺寸/Size:2mm²(1*2mm), 400mm²(20*20mm),2500mm²(50*50mm)或其它尺寸

厚度/Thickness:约0.06mm

熔点/Melting point:960℃

密度/Density : 10.49g/cm3(25℃)(lit.)

沸点/Boiling point : 2213℃(lit.)

硬度/Hardness :  高/high

灼热丝银箔特点/Product features

本司向国内知名金属厂商批量定制,采用新一代冷压冷扎,缎压,清洗等工艺,严格控制8个金属元素,杂质控制在0.01以内,采用多辊压延自动收片平整光滑。外表、纯度和物性等远大于小工作坊制作的银箔。

其它配件/耗材:

灼热丝试验仪: http://www.ag17.wang/flamechamber/IEC60695_2_10_Glow_Wire.html

灼热丝校温银箔,灼热丝U型头,热电偶线等:http://www.ag17.wang/haocai/product_437_1.html


灼热丝标准要求:

GB/T5169.10灼热丝温度测量系统和校验

可将一件纯度至少为99.8%,面积约2mm² 和厚度约0.06mm的银箔放置在灼热丝顶部的上表面来完成灼热丝温度的单点确认。将灼热丝以适合的低加热速率进行加热,当银箔开始融化时,温度计应该显示960℃±15℃(IEC60695-2-10:2013新标准,GB/T5169.10标准为960℃±15℃),确认程序完成之后,应在灼热丝还是热的时候立即清除所有银残余物,以减少融成合金的可能性。在争议情况下,应采用银箔确认方法。

IEC60695-2-10Verification of the temperature measuring system

A one-point verification of the temperature of the glow-wire can be performed using a foil of silver with a purity of at least 99,8 %, approximately 2mm² and 0,06 mm thick, placed upon the upper surface of the tip of the glow-wire. The glow-wire is heated at a suitably slow heating rate, and, when the foil starts to melt, the thermometer shall indicate 960 °C ± 15 °C. The glow-wire, while still hot, shall be cleared of all traces of silver immediately after this verification process to reduce the probability of alloying. In case of dispute, this verification method using a silver foil shall be used.

灼热丝校温方法:

1.为何灼热丝头达960度时不能用其它比较直观的仪器测量出比较准确的数值,因为银的熔点为960摄氏度,所以要用高纯度的银箔校温。

2裁剪一块纯度不小于99.8%,厚度约0.06mm, 面积约2mm²的银箔片;

3.用镊子夹持放置在灼热丝U型头的端点上面,缓慢施加灼热丝电流,当温度处于960度时银箔片熔化(在U型头表面凝结成水银颗粒状),即表明灼热丝温度达到标准要求。每次校温完毕及时清除灼热丝顶部的银残余物,如使用软钢丝刷或软金属刮片等。

4.如校温不合格,损耗较重的灼热丝要及时更换新的再重新校温。

5.IEC60695-2-10:2013新标准要求为960℃±15℃,对灼热丝仪器厂家更严格要求。

灼热丝校温银箔检测

0.06mm灼热丝银箔99.99纯度检测报告




安规仪器网/美华安规仪器---追崇原创、重视知识产权和尊重劳动成果,也是行业发展主旨,禁止盗链、采集、复制及转载等非法行为,一经发现保留追责权力。


标签:   灼热丝 银箔 Glow-wire
  • 上一条
  • 下一条