JWDS0028 Power Plug Tracking Test Service

JWDS 0028 Power Plug Tracking Test Service

Tracking on power plugs as such does not necessarily lead to fire accidents. The problem being, rapid flaming occurs on the connection interface between the plug and the mains outlet as a result of repeated small spark discharges (scintillation). Prevention is important as this phenomenon can ignite flammable items nearby, thus likely leading to fire accidents. We at OKI Engineering provide test services to prevent such tracking from occurring.

Chinese version test method|中文版测试方法: http://www.ag17.wang/testing/testing669.html


 JWDS0028漏电起痕陶瓷片|JWDS0028 Ceramic chip of Testing 

美华安规仪器|安规仪器网---独家提供大中华区日本进口的JWDS0028试验用陶瓷片,多个大陆,台湾等机构,插头厂家,电源生产厂家及出往日本的采购商均有订购本司陶瓷片。咨询QQ:49327-8805/86-15502036348/邮箱:sm@ag17.wang

JWDS0028漏电起痕陶瓷片:http://www.ag17.wang/haocai/haocai477.html

About the Tracking Phenomenon

Tracking occurs when voltage is applied on a surface polluted with or damaged by salt, dust, moisture and chemical agents (synthetic detergents) as current flows beyond insulation creepage distance while the surface deteriorates and a carbide conductive path (track) is created with consequent insulator breakdown.

Tracking Resistance Test for Power Plugs

Test parameters are designed for tracking resistance capability of an indoor use, rated voltage 125V, rated current 15A or less, plug with molded cable.

"Tracking Resistance of Power Plugs" JWDS0028.
A standard by the Japan Electrical Wiring Devices and Equipment Industries Association, JEWA.

LevelAnti-tracking performanceUsage environment
Frequency of insertion/removalLocation
1Drop frequency: over 200 timeslowLocation difficult to inspect
Moisture Location
Specific location
2Drop frequency: over 80 timeslowGeneral location
highMoisture Location
Specific location

Case Study of Tracking Resistance Test

  • Sample

  • AC Adaptor (input: AC100-240V, output: DC5V)

  • Test liquid (solution)

  • 0.2% aqueous solution of ammonium chloride

  • Applied voltage

  • Power plug rated voltage of AC125V, 50Hz

  • Other test conditions

  • • Single drop amount: 20mm² (+5, -0mm²)
    • Continuous dropping in intervals of 5 minutes ±10 seconds
    • Drop frequency: 80 times
    • Test circuit as in Figure 1
    • Used equipment: AC-stabilized power supply.


  • Tracking resistance test: with smoke generation

  • Power plug tracking resistance test. Figure 1: Test Circuit
    Figure 1: Test Circuit

As for the test result, we confirm that no flaming occurs from either of the following phenomena:

  • Flaming during dropping

  • Overcurrent relay or circuit breaker operation

  • Broken test outlet cover

NOTE: Not accounting for scintillation and smoke without generating fire.