UL817|UL498|UL588|UL507|UL插頭|UL保險絲插頭測試專案要求|UL Power cord/UL Fuse Plug Testing Program

UL817|UL498/CSA 22.2No.42檢測設備清單/Test equipment lists:

http://www.ag17.wang/plugtester/UL498_UL817_C22.2No.42_Test_Equipments_1.html
其他檢測設備/Othertest equipment lists:http://www.ag17.wang/case/

(817/SB9)

Conductor Securness Test (20 lbf/1 min)   導體牢固性測試:≥18AWG,20Lbf/1min;<18AWG,8Lbf/1min;導體連接不得斷開

(817/82)

Security of Blades Test (20lbf, 2min)   插銷牢固性測試:20Lbf/2min,撤銷重物後插銷位移≤2.4mm

(817/83)

Security of Insulation Test (15lbf, 2min) 絕緣牢固性測試:15Lbf/2min,絕緣不得從插頭本體滑脫或出線口不可見導體

(817/SB10)

Strain Relief Test (30 lbf) (may be 7D aging) 應力消除測試:30Lbf/1min,應力不得傳遞到導線連接處,輔助機械保護的應力消除夾需7天/90±2℃老化,先施拉力後耐電壓

(817/87)

Temperature Test (max. 30oC raise)  溫升測試:通配線額定電流;插銷溫升≤30℃

(817/88)

DVW (1250 V)  介質耐壓測試:線芯與線芯間施加1250V/1min,無擊穿

(817/89)

Insulation Resistance Test絕緣電阻測試:相反極性間、帶電件與可觸及外表面間;阻值≥100MΩ

(817/90)

Accelerated Aging Test (96 Hrs, 100 oC) 加速老化測試:100±1℃/96小時;無開裂、變色和其他肉眼可見的老化現象

(817/92)

Impact Resistance Test (7days, 90 oC) 耐衝擊測試:老化條件90±1℃/7天,跌落撞擊1000次;樣品不得變的不可使用或帶電件外露可觸及

(817/94)

Attachment Plug Grip Test插頭握持試驗:3次試驗必須2次試驗拉力比≥0.55

(817/95)

Blade Pull at Elevated Temperature Test   插銷高溫拉力試驗:10Lbf/60℃/4小時,每個插銷4個側面位移平均值≤1.6mm(6個樣品/6inch長軟線)

(817/96)

Flexing Test (2500 cycles)  彎曲試驗:180°,10次/分鐘,113g,2500次;任一芯線不得斷路(6個樣品/20inch長軟線)

(817/99)

Abrupt Pull Test突拉試驗

(817/100)

Jacket Retention Test 護套保持試驗

(UL817/60.2)

Adhesion Test  軟線與插頭本體附著性測試(14-50P插頭)(OUTDOOR戶外型)

(817/101.2)

Calibration Test 校準試驗:3個樣品分別通額定電流的135%、150%、200%,樣品分別在60分鐘、10分鐘、2分鐘斷開電路且外殼不得有任何形式的燒焦或破裂

(817/101.3)

Short-circuit Test  短路試驗:120V/200A和1000A/60HZ,20A延時熔斷器;棉層不得被點燃,軟線不得燃燒或熔化以致導體裸露

(817/101.5)

Abnormal Test  非正常操作測試:3個樣品分別通額定電流的110%、135%、150%,樣品分別在420分鐘、60分鐘、10分鐘,棉層不得點燃、軟線不得燃燒或熔化以致導體裸露

(UL817/SB11.2)

Crushing Test   抗壓試驗:90±1℃/7天→冷卻至室溫→75Lbf/1分鐘恒定壓力(12.7mm厚木板,垂直和水準)(OUTDOOR戶外型)

(UL817/SB12.2)

Temperature Test  過電流保護裝置:通額定電流的110%、125%、150%、175%、200%/7小時或至裝置電路斷開(OUTDOOR戶外型)

(817/102)

Cord Tag  軟線標籤耐久性測試:5Lbf/1分鐘,標籤撕裂長度≤1.6mm,在軟線在移動≤13mm

(498/60)

DVW 介質耐壓測試:線芯與線芯間施加AC1000+2*額定電壓V/1min,無擊穿

(498/58)

Mold Stress Relief Test   模壓應力消除試驗:70℃/7小時→冷卻至室溫→按498/60條進行耐壓測試

(498/59)

Moisture Absorption Resistance Test 耐潮濕試驗:105±5℃/1小時乾燥,秤重W1;然後將試品放入23±1℃/24小時水中,擦乾淨試樣表面水漬,秤重W2;(W2-W1)/W1×100%≤6%

(498/68)

Conductor Securness Test (20lbf, 1min)  導體牢固性測試:≥18AWG,20Lbf/1min;<18AWG,8Lbf/1min;導體連接不得斷開

(498/96)

Strain Relief / Integrity of Assembly  裝配完整性試驗:≥18AWG,30Lbf/1min;<18AWG,20Lbf/1min;插頭本體不得有破損,導體不得外露

(588/40)

Leakage Current Test 洩漏電流測試

(588/41)

Leakage Current Test following Humidity Conditioning 潮濕處理後洩漏電流測試

(588/58)

Enclosure Mold Stress Relief Test 外殼模塑應力消除測試

(588/59)

Drop Test 跌落測試

(588/60)

Impact Test 撞擊測試

(588/67)

Fuseholder Tempreature Test 熔絲座溫度測試

(588/69)

Fuseholder Cover Test 熔絲座蓋強度測試

(588/71)

Strain Relief Test 應力消除測試

(588/72)

Reliability of Conductor Connections Test 導體連接可靠性測試

(588/90)

Flexing Test 彎曲測試

(588/91)

Temperature Test after Flexing 彎曲後溫度測試

UL 507 標準本身並無針對插頭做測試及評估的條文.  貴司申請的產品為UL 817 插頭, 且因貴司的插頭為帶Fuse 的特殊結構,所以除了UL 817 外, 尚需引用到部分 UL 588 針對 Fuse 插頭的測試要求.UL817插頭使用於UL507風扇時,所配電源線必須增加-R type測試  
UL62 –R type電源線要求:
1.   僅適用於UL 507風扇
2.   電源線參數14-18 AWG,300 V
3.   超載保護不能超過5A,可拆
4.   所配插頭必須為NE

 